Configurable code lengths, Configurable code lengths –9, Enable modulus 8 filter on bar & space counts – GoDEX GS220 User Manual
Page 16: Disable modulus 8 filter on bar & space counts, Handle code 39 bad border, Disable code 39 bad border, Code length lock #1, Code type lock #1

2–9
³
9
0
1
8
0
0
~ Minimum Symbol Length
– Single-line default
is 3. Combine this code with the proper code bytes
(on page 1
2–1), to specify the minimum number
of characters in all non-UPC/EAN bar codes.
³
9
0
1
9
0
0
~ Symbol Length Lock
– Combine this code with
the proper code bytes, to lock the bar code’s
length into place.
³
1
1
9
4
1
7
Enable Modulus 8 Filter on Bar & Space
Counts
³
1
1
9
4
0
7
* Disable Modulus 8 Filter on Bar & Space
Counts
³
1
0
0
7
1
2
Handle Code 39 Bad Border
³
1
0
0
7
0
2
* Disable Code 39 Bad Border
Configurable Code Lengths
There are seven bar code lock lengths available. Specific code types can be
assigned to a lock length.
While in configuration mode:
1. Scan the code
length lock #1 bar code (below).
2. Scan the three code bytes that represent the code length
2–1).
3. Scan the matching code
type lock #1 bar code (below).
4. Scan the three code bytes that represent the code type (on page 1
2–1).
This process can be repeated for lock lengths 2 through 7.
³
9
0
2
0
0
0
~ Code Length Lock #1
³
9
0
2
1
0
0
~ Code Type Lock #1