0 operating instructions – Go Power! GP-PWM-25 User Manual
Page 11

Owner’s Manual | GP-PWM-25 Regulator
11
© 2010 Carmanah Technologies Corporation
Last revised: March 2010
6.0 Operating Instructions
Power Up
When the GP-PWM-25 is connected to the battery,
the GP-PWM-25 will go into Power Up mode. The
controller will select the battery voltage automatically.
If the battery voltage is above 20 Volts the controller
assumes a 24 Volt battery system.
Icons Displayed: Three horizontal dashes
Setting the Battery Type / Charging Profile
Set the Battery Type / Charging Profile by holding
down the B Button for 10 seconds. When the display
begins blinking you may set the Battery Type by
toggling through the Charging Profile numbers 1, 2 or
3 by pressing the B Button.
Refer to the Battery Charge Profile Chart on the
following page for details on each profile.