beautypg.com

0 maintenance – Go Power! GP-3000HD User Manual

Page 15

background image

Go Power! Modified Sine Wave Inverter

Owner’s Manual

www.gpelectric.com

15

Problem and Symptoms

Possible Cause

Solution

Thermal shutdown.

Allow inverter to cool off. Reduce
load if continuous operation
required.

No output voltage, Error indicator
on, load in excess of:

3000 W: 250 A

Very High Power load

Remove or lessen load

No output voltage, Error indicator
on, load less than:

3000 W: 250 A

Thermal shutdown.

Improve ventilation; make sure
ventilation openings in inverter are
not obstructed. Reduce ambient
temperature.

No output voltage, Error indicator
on

Short circuit or wiring error.

Check AC wiring for short circuit to ground or improper wiring.



7.0 Maintenance

Very little maintenance is required to keep your inverter operating properly.

Keep the exterior of the inverter clean and dry. Unplug the inverter before cleaning.
Periodically clean the outside of the inverter with a soft, dry cloth to prevent accumulation
of dust and dirt; never use water or harsh cleaners.

When cleaning the inverter, confirm the screws on the DC input terminals are tight.