HOW TO USE YOUR APPLIANCE

- 12 -

Filling Loop
Connect the filling loop at the filling tap.
With the Central Heating flow isolation

valve open as indicated in the diagram.

Open the cold water inlet tap. Slowly turn

the filling tap until the correct pressure is

indicated on the display.
Disconnect the filling loop at the filling tap.
If the loss of pressure problem persists,

you must contact your Installation/

Servicing company or Glow-worm Service.

10 Appliance safety devices

10.1 Boiler Shutdown
The boiler software is designed to

recognise the potential for an overheat

lockout and will shutdown before this

happens.
• To restart the boiler, press the reset

button, see chapter "How to use your

appliance ► Overview".

If the boiler fails to resume normal

operation and all external controls are

calling for heat, then call your Installation/

Servicing company or Glow-worm service.

10.2 Protecting against frost
Appliance Protecion
In case of the risk of frost:
• Make sure that the electrical and gas

supply to the appliance is turned on.

• For an absence of several days, you

can leave the appliance to run normally.

The appliance has a built in frost

protection device that protects the boiler

from freezing. With the gas and electric

supplies ON and irrespective of any room

thermostat setting, the frost protection

device will operate the pump when the

temperature of the boiler water falls

below 8

O

C. A timer is used so that the

temperature can be checked periodically.

After 10 minutes the pump will be stopped

if the temperature is higher than 10

O

C or

has already reached 35

O

C. The burner

will activate if the boiler temperature

does not reach 10

O

C after 30 minutes or

at any time if the temperature drops to

5

O

C. The burner will switch off when the

temperature reaches 35

O

C.

The appliance always has frost protection

active when the power and gas supply are

on.
System Protection
The boiler alone cannot ensure that the

installation is protected against frost.

NOTE: Any other exposed areas of the

system should be protected by a separate

frost thermostat.
In case of prolonged absence, where

power to the dwelling and the boiler is

switched off, contact your Installation/

Servicing company or Glow-worm Service

to have the installation drained or to have

the heating circuit protected by adding an

anti-freeze specially designed for heating

systems.

CAUTION: Your domestic

water circuit (hot and cold) is

not protected by the boiler.

10.3 Condensate Drain Blockage
As a safety feature the boiler will stop

working if the condensate drain becomes

blocked. During freezing conditions this

may be due to the forming of ice in the

condense drain external to the house.
• Release an ice blockage by the use of

warm cloths on the pipe.

The boiler should then restart.