beautypg.com

How to use your appliance – Glow-worm Flexicom cx User Manual

Page 11

background image

0020127401_00 - 06/11 - Glow-worm

HOW TO USE YOUR APPLIANCE

- 11 -

• The boiler will operate automatically.
• NOTE: The display will indicate the

Heating system water temperature or a

fault code (see section Fault Finding).

• The control panel will flash and display

all its digits. It will then return to the

default display and depending on the

selected operation and controls, display

the temperature settings and water
pressure.

Pre heat
Comfort feature to maintain the Domestic

Hot Water temperature, which improves

the response time of hot water at the tap.

To access the Pre Heat function hold in

the "+" button for 5 seconds. The display

will indicate (flashing) if it is ON/OFF(OF).

Pressing the "-" button will switch the Pre

Heat OFF and pressing the "+" button will

switch it ON. After 5 seconds of inactivity

the display will reset to indicate the water

pressure.
Switching off - Central Heating mode
• Press the "-" selector button to turn

OFF the Central Heating.

All the appliance functions will be switched

off, except frost protection.

ANY ASSISTANCE?

9 Fault Finding

In this section fault codes that are

displayed, which CAN be carried out by

the USER to restore appliance operation

(Corrective action: ...). Other fault codes

MUST be solved by a competent person

only.

Like all condensing boilers

it will produce a plume of

condensation from the flue

terminal in cool weather.

This is due to the high

efficiency and hence low flue

gas temperature of the boiler.

It is normal and not a fault

indication.

If any fault persists, and your appliance still

does not work, leave it switched off and

contact your competent person.

9.1 Electrical Supply Failure

The boiler will not work without an

electrical supply and normal operation

of the boiler should resume when the

electrical supply is restored.
If the boiler does not resume normal

operation, check the external controls.
It may be necessary to restart your

appliance.

• To restart the boiler, press the reset

button, see chapter "How to use your

appliance ► Overview".

9.2 Appliance fails to light

The LCD will display a flashing 'F' and

code number,

• To restart the boiler, press the reset

button, see chapter "How to use your

appliance ► Overview".