beautypg.com

13 fault finding, Yes no – Glow-worm Compact 100E User Manual

Page 31

background image

31

221894A

Check continuity of clock/timer harness, ensure an electrical supply is available at the clock,
ensure that remote controls are calling for heat, ensure the override switch, if fitted, is in overide position.

NB. The clock can be by passed by refitting the plug link which should be inside the clock timer cover.

Isolate electrical supply, set clock to an on period.
Is there continuity across common and heating?

Does clock keep time?

NO

Clock/timer in order if no central heating,
refer to main fault finding.

Set clock to off period. Is there continuity across
common and heating on?

NO

Faulty clock/timer.
Replace.

NO

Faulty clock/timer.
Replace.

Faulty clock/timer.
Replace.

YES

YES

YES

Check continuity of clock/timer harness, ensure an electrical supply is available,
ensure that remote controls are calling for heat.

NB. The clock can be by passed by refitting the plug link which should be inside the clock timer cover.

Isolate the boiler from electrical supply remove outer case.

Disconnect and insulate the cables
from heating common and heating on.

Switch on electrical supply,
is there a display on clock/timer?

NO

Clock/timer in order if no central heating,
refer to main fault finding.

Advance clock/timer until a demand is indicated
Is there now continuity between heating
common and heating on?

YES

Faulty clock/timer.
Replace.

Faulty clock/timer.
Replace.

YES

YES

YES

NO

13 Fault Finding

DIGITAL CLOCK/TIMER FAULT FINDING

Diagram 13.4

7461

7463

Diagram 13.5

ELECTRO/MECHANICAL CLOCK/TIMER FAULT FINDING

YELLOW

YELLOW

ORANGE

PURPLE

(L)

(N)

EXTERNAL

CONTROLS

PLUG FROM CLOCK/TIMER