TECHNICAL DATA

5 betacom

2

Boiler, type C13, C33, C43

Description

Unit

24

28

Gas category

ll

2H3P

ll

2H3P

SEDBUK rating 2009

%

89.0%

88.5%

Heating
Maximum heating input power

kW

18.5

24

Minimum heating output power at

80/60°C (P min.)

kW

7.7

8

Maximum heating output power at

80/60°C (P max.)

kW

18.0

23.3

Minimum heating output power at

50/30°C (P min.)

kW

8.5

8.8

Maximum heating output power at

50/30°C (P max.)

kW

19.6

25.3

Minimum heating temperature

°C

10

10

Maximum heating temperature

°C

80

80

Minimum heating flow rate

l/h

400

400

Content of heating expansion

vessel

l

8

8

gallons

1.76

1.76

Heating expansion vessel preset

pressure

bar

0.75

0.75

psi

10.9

10.9

Maximum heating system volume

(approx)

l

160

160

Heating safety valve preset

pressure (PMS)

bar

3

3

lbf/in²

36/3

36/3

Domestic Hot Water
Minimum DHW output power (P

min.)

kW

8

8

Maximum DHW output power (P

max.)

kW

24

28

Maximum DHW temperature

°C

60

60

Specific flow rate (∆T of 35 K)

l/min

9.8

11.5

Minimum inlet water pressure

bar

0.3

0.3

psi

4.3

4.3

Maximum inlet water pressure

bar

10

10

psi

145

145

Combustion
Appliance NOx class

5

5

Electrical

Electrical supply

V/Hz

230V /

50Hz

230V /

50Hz

Standby mode electrical power

W

6

6

Operational mode electrical power

(Max)

W

151

151

Internal fuse rating on main PCB

A

2

2

Index of electrical protection (EN

60529)

IPX4D

IPX4D

Description

Unit

24

28

Gas connection Ø O.D.

mm

15 (copper) 15 (copper)

Heating flow and return connection

Ø O.D.

mm

22 (copper) 22 (copper)

Domestic Hot Water connection

Ø O.D.

mm

15 (copper) 15 (copper)

Condensate connection Ø I.D.

mm

Pushfit

Plastic

Pushfit

Plastic

Safety valve discharge connection

Ø O.D.

mm

15 (copper) 15 (copper)

Lift weight

kg

37

38

lb

82

84.8

Total weight (installed)

kg

42

43

Number of CE certificate

1312 BU

5334

1312 BU

5334

Description

Unit

24

28

Natural Gas G 20 (15 °C, 1013.25 mbar)

Maximum DHW gas flow rate

m

3

/h

2.54

2.96

Maximum heating gas flow rate

m

3

/h

1.96

2.54

Minimum gas flow rate

m

3

/h

0.85

0.88

CO

2

at Qmax DHW + "tolerance

case ON"

%

9.2 ± 0.3% 9.2 ± 0.3%

CO

2

at Qmax DHW + "tolerance

case OFF"

%

9.0 ± 0.2% 9.0 ± 0.2%

CO

2

at Qmin +

"tolerance case ON"

%

8.9 ± 0.3% 8.9 ± 0.3%

CO

2

at Qmin +

"tolerance case OFF"

%

8.7 ± 0.2% 8.7 ± 0.2%

Inlet pressure

mbar

20

20

Propane Gas G 31 (15 °C, 1013.25 mbar)

Maximum DHW gas flow rate

kg/h

1.87

2.17

Maximum heating gas flow rate

kg/h

1.44

1.87

Minimum gas flow rate

kg/h

0.62

0.645

CO

2

at Qmax DHW + "tolerance

case ON"

%

10.3 ±

0.3%

10.3 ±

0.3%

CO

2

at Qmax DHW + "tolerance

case OFF"

%

10.1 ±

0.3%

10.1 ±

0.3%

CO

2

at Qmin +

"tolerance case ON"

%

9.8 ± 0.3% 9.8 ± 0.3%

CO

2

at Qmin +

"tolerance case OFF"

%

9.6 ± 0.2% 9.6 ± 0.2%

Inlet pressure

mbar

37

37

TECHNICAL DATA