17.6 Expansion vessel

1

2

Key

1 Expansion vessel

2 Expansion vessel pressure inlet

• Check the expansion vessel's supply pressure (see « Technical

Data » chapter) by means of the pressure inlet located on the

expansion vessel. Adjust the pressure if necessary.

• Following the installation of a new expansion vessel, fill and

purge the appliance or installation, if necessary.

17.7 Condensate trap

a

Warning:

condensate is mildly acidic. Use protective gloves.

5

3

2

4

1

6

Key

1 Condensate cleaning cap

2 Condensate pipe

3 Condensate outletv

4 Condensate retaining screw

5 Condensate trap

6 Hose

• Place a container under the condensate trap (5).

• Remove the condensate from the reservoir (1).

• Disconnect the condensation discharge (2).

• Disconnect the heat exchanger hose (6).

The condense trap will contain water, lift taking care not to spill

the water.

• Remove the condensate trap (5) using the retaining screw (4).

• Clean the hose, the trap and the siphon, remove any

accumulated dirt.

• Reassemble the components, taking care to position the

gaskets correctly.

• Start the siphon (3) and fill with water.

MAINTENANCE