5.2 Control Thermistor Phial

Route the cable well clear of any part of the back boiler which
becomes hot. Push the phial into the pocket and secure with
retaining wire from fittings pack, see diagram 5.4. Again make
sure that the cable is not touching the casing.

5.3 Boiler Control Box

Taking care that the POWER IS OFF, wire the incoming mains
cable to the mains plug supplied in the fittings pack. Do not
connect the mains supply plug to the control box socket, see
diagram 5.5.

5.4 Boiler User Control lead fitting,
Chatsworth 4 and Dovedale 4 only.

Before the fire front is positioned the boiler user control will need
to be fitted to the control box.

Remove the control box lid securing screws, see diagram 5.5.

Remove the control box lid taking care not to damage the
insulation.

5 Electrical Wiring

L
E
N

SECURING
SCREWS
(4)

Diagram 5.6

9634

CONNECTING
LEAD

CABLE
GRIP

SECURING
SCREW

SUPPORT
BRACKET

INSERT
RETAINING WIRE
AND SECURE