5.1 General

WARNING. This boiler must be earthed.

ISOLATE THE ELECTRICAL SUPPLY BEFORE DOING ANY
WIRING

All of the electrical installation must be correctly earthed and be
in accordance with the current issue of BS7671 and be carried
out by a competent person.

The boiler electrical supply is 230V~ 50Hz, fused at 3A. A
double pole isolating switch, having a minimum contact
separation of 3mm in both poles should be used.

The boiler does not require a permanent live. External controls
are connected to the live 'L' terminal in the 3 way plug, as an
example see diagram 5.1.

Supply cable should be (85

o

C) PVC insulated type to the current

issue of BS6500 Table 16, not less than 0.75mm

2

(24/0.20mm).

NOTE: The supply to the boiler and any remote control must be
through the same isolating switch or plug and socket.

It is preferable to have the boiler electrical supply cable entering
the builder’s opening at the left, see diagram 5.2. Keep the cable
well clear of hot surfaces.

If right hand access is required and the boiler electrical supply
cable has to be routed down the right hand side of the combustion
chamber keep the cable well clear of hot surfaces. The cable
must also be routed in front of the gas control valve, see diagram
5.3.

Note: If the fire front to be fitted to the back boiler unit is, a Firelite
4, Contour 4, Miami 4, Heartbeat 4, or Black Beauty 4, the mains
cable, if it is routed from the right, will have to be secured in a
retaining clip on the combustion chamber extension. Fitting
instructions for the combustion chamber extension are given in
the Use, Installation and Servicing instructions of the above fire
fronts.

NOTE: The boiler electrical supply cable must not be
routed along the back of the appliance.

The cable must be kept well clear of hot surfaces.

When fitting the back boiler unit do not trap the cable.

5 Electrical Wiring

Diagram 5.2

Diagram 5.3

11615

9636

ELECTRICAL
SUPPLY CABLE

ELECTRICAL
SUPPLY
CABLE

Diagram 5.1

6452

Froststat

Pipestat

Roomstat

Programmer

Pump

L

N

E

L

N

E

Double
Pole
Switchspur

3 Way

Plug at

Appliance

(Left hand shown)

(Right hand shown)