Attaching dust intake ports, Alternate setup – Delta 50-761 User Manual
Page 10
10
Fig. 5
Fig. 4
ATTACHING DUST INTAKE PORTS
Place dust intake port (A) Fig. 7 over intake hole (B)
opposite the motor. Align four holes (C) in the port with
the ones in the motor/blower assembly and fasten with
four M4 sheet metal screws.
Turn unit over so casters are on the ground.
BECAUSE OF THE WEIGHT OF THE
UNIT, MORE THAN ONE PERSON
SHOULD LIFT MOTOR/BLOWER ASSEMBLY INTO
UPRIGHT POSITION.
A
B
Fig. 7
B
C
ALTERNATE SETUP
The steps so far will assemble the unit with the motor
on top and dust intake ports on bottom, as shown in
Fig 4.
This unit can be assembled with the intake port (B) Fig.
5 in the up position by following the steps in “LEGS
TO MOTOR/BLOWER ASSEMBLY.” The exception is
to place the motor/blower assembly on a flat surface
with the motor (A) Fig. 6 facing up before attaching
legs.
NOTE: BEFORE DOING THE ALTERNATE SETUP,
REMOVE 5/16” HEX HEAD SCREWS FROM HOLES
(B) FIG. 6 IN MOTOR/BLOWER ASSEMBLY AND
PLACE IN HOLES (C). AIR LEAKAGE WOULD
OCCUR IF SCREWS ARE NOT PLACED IN HOLES
(C).
A
B
C
Fig. 6
DISCONNECT MACHINE FROM POWER
SOURCE