EMM Labs XDS1 User Manual
Page 19
019
Appendix A - Serial Remote Control (RS232)
Serial Remote Control (RS232)
The XDS1 V2 is equipped with a 9-pin RS232 port for system remote control via a serial
cable (not provided by EMM Labs). Please use a standard RS232 cable. Do not use a null
model cable, as this will not work. RS232 communication port settings:
• 19,200 baud
• 8 bits
• 1 stop bit
• no flow control
• no parity bit
Commands to the XDS1 V2
All commands sent to the XDS1 V2 consist of 3 ASCII characters (all lowercase) followed by
a carraige return or
commands are not stored in a stack. They need to be sent in intervals of at least 50ms to
allow enough time for the XDS1 V2 to execute a command before receiving the next one.
Command
Function
ply
Start Playback
pse
Pause Playback
stp
Stop Playback
mod
Toggles through the SACD playback layers. Only works when not playing.
rpt
Toggles through the different repeat modes
nxt
Jumps ahead a track
prv
Jumps back a track
© 2013 EMM Labs Inc., All Rights Reserved. EMM Labs reserves the right to amend specifications & design without notice.
XDS1 V2 CD/SACD PLAYER OWNER’S MANUAL