18 - SYSTEM TROUBLESHOOTING

TABLE 7 - SYSTEM TROUBLESHOOTING

No Or Insuffi cient Domestic

Hot Water

If installed with indirect water heater, insure end switch in relay box

controlling indirect water heater is properly connected to cable 2 (see

wiring diagram). This insures domestic water calls are prioritized. If cable

2 is not used, turn Economy Feature OFF.

House Will Not Get Or Stay

Warm

1.

Check for air bond radiators.

2.

Check thermostat settings including het anticipator settings (common

on non-digital thermostats).

3.

Check Economy settings. Economy feature, much like outdoor reset

controls, lowers average boiler temperature, can slow or prevent

house from coming up to temperature. Move to lower setting.