beautypg.com

As needed – Ditch Witch SK750/SK755 User Manual

Page 68

background image

SK750/SK755 Operator’s Manual

Service - 67

As Needed

CMW

®

As Needed

Change Air Filter

Change air filter when red band on indicator (1) is
visible. Replace safety element (4) every third
change of primary filter (3) or any time primary
element has become damaged.

1.

Open air filter housing at latches (2).

2.

Remove primary element (3).

3.

Wipe inside of housing and end cup (2).

4.

Insert new primary element.

5.

Latch air filter case.

6.

Reset air filter service indicator (1).

Location

Task

Notes

Change air filter

Check battery

Charge battery

t35om032w.eps

1

3

2

4