Ditch Witch SK750/SK755 User Manual
Page 62
SK750/SK755 Operator’s Manual
Service - 61
50 Hour
CMW
®
Change Hydraulic Filter (initial)
Change hydraulic filter after 50 hours.
Check Fan Belt for Tension and
Damage
Check belt tension every 50 hours. Belt is
properly tensioned when it moves about 1/4-3/8”
(7-9 mm) when pushed at the long span. Replace
the belt when it is worn and sinks into the pulley
groove.
Adjust Tension
1.
Loosen two alternator bolts (shown).
2.
Adjust position as needed.
3.
Tighten bolts.
4.
Check tension.
Check Fuel Hose and Clamp Bands
Check fuel hose and clamp bands every 50
hours.
If the clamp is loose, apply oil to the threads and
retighten it. If the hose is worn, replace it.
Bleed the fuel system if the hose and/or clamp is
changed.
t35om019w.eps
See also other documents in the category Ditch Witch Special machinery:
- JT5 (161 pages)
- JT922 (159 pages)
- JT9 (165 pages)
- JT20 (195 pages)
- JT1220 (201 pages)
- JT2020 (203 pages)
- JT25 (203 pages)
- JT30 (245 pages)
- JT60 (218 pages)
- JT100 (243 pages)
- AT Air Hammer (11 pages)
- TK Series Manual (61 pages)
- 8500 (77 pages)
- MR90 (121 pages)
- FT5 (28 pages)
- FM5 (57 pages)
- FM13V (46 pages)
- FM25 (67 pages)
- P80 (71 pages)
- OnGrade (63 pages)
- FX20 (100 pages)
- FX25 (119 pages)
- FX30 (149 pages)
- FX50 (141 pages)
- FX60 (157 pages)
- MV800 (111 pages)
- RT Line (115 pages)
- RT30 (97 pages)
- RT45 (203 pages)
- RT55 (177 pages)
- RT100 (161 pages)
- RT115 (252 pages)
- RT120 (223 pages)
- Zahn (105 pages)
- RT80 (203 pages)
- RT115 Q (193 pages)
- RT120 Q (211 pages)
- 100SX (50 pages)
- 410SX (131 pages)
- SK350 (77 pages)
- SK850 (107 pages)
- SK850 Footings Machine (107 pages)
- 150RT (55 pages)
- 250RT (49 pages)