beautypg.com

DaySequerra Remote Dashboard User Manual

Page 10

background image

10    

Ethernet Configuration Guide 

Enable Preset Scan – will allow you to scroll through all of your stored preset stations. Enter the time
in seconds that you would like to remain on each station in the Dwell box.

NOTE: The Preset stations that are stored in the Remote Dashboard application are NOT the same
presets that are stored on your DaySequerra unit.

Alarm Status – White indicates that no alarms have been enabled

Green indicates that there are alarms enabled

Red indicates that an alarm has been triggered and will be listed in the boxes below

See figure 3.0


Remote IP Connection
– White indicates that there is no Remote IP connection established

Green indicates that the Remote IP has been connected

IP Address – enter the IP address of the unit that you are trying to connect and press
the connect button


Analog RF Signal Strength – White indicates that no analog signal is present

Green indicates that an analog signal is present

RF Level – indicatesthe current level of the analog signal in dBf
Alarm Under – enter the threshold that you would like to set the alarm if the signal
strength falls below and press the SET button under alarm


Digital Program Status – Each box from HD-1 to HD-8 will light Green for all of the available HD
signals present for the current station. You can select one Digital Audio signal at a time. HD-1 is the
default. The Digital Audio will indicate Green on the selected HD signal. To switch the HD-2 to HD-8
press the Select button

under the desired box. Once the HD signal switches and is locked the

indicator will change from White to Green.

You can alarm the digital signal present for the HD signal that you have selected by pressing SET
next to the Alarm in each box.

Program Alarm – once you have set any alarm in any box you must press Enable to have the
Alarms become active. To Disable all of the alrams set, press Disable.

See Figure 2.0


Once an alarm has been triggered it will be displayed in the Alarm Status box. To clear the alarms
press the Clear All button.