Preliminary – Clay Paky STORMY CC User Manual
Page 25

25
PRELIMINARY
Channel Mode
DMX
Value
Function
Standard Independent
GREEN RATE
0 - 5
Light OFF
6 - 255
Flashing at linearly variable frequency from low:
(~0.3 flashes/sec or 1 flash every period of 3.5sec)
to high (25 flashes/sec or 1°flash every period of 40msec)
See details in a following dedicated table.
BLUE INTENSITY
0 - 255
Blue colour linearly increase from no-light to maximum intensity
BLUE DURATION
0 - 255
Light time (versus dark time) linearly increases from shorter time
(2.5msec) to longer time (650msec)
See details in a following dedicated table.
IMPORTANT:
Duration Time must be lower than Rate Time (Period) for flashing.
If Duration Time is equal or greater than Rate Time (Period) the light
is continuously on.
BLUE RATE
0 - 5
Light OFF
6 - 255
Flashing at linearly variable frequency from low:
(~0.3 flashes/sec or 1 flash every period of 3.5sec)
to high (25 flashes/sec or 1°flash every period of 40msec)
See details in a following dedicated table.
WHITE INTENSITY
0 - 255
Blue colour linearly increase from no-light to maximum intensity
WHITE DURATION
0 - 255
Light time (versus dark time) linearly increases from shorter time
(2.5msec) to longer time (650msec)
See details in a following dedicated table.
IMPORTANT:
Duration Time must be lower than Rate Time (Period) for flashing.
If Duration Time is equal or greater than Rate Time (Period) the light
is continuously on.
WHITE RATE
0 - 5
Light OFF
6 - 255
Flashing at linearly variable frequency from low:
(~0.3 flashes/sec or 1 flash every period of 3.5sec)
to high (25 flashes/sec or 1°flash every period of 40msec)
See details in a following dedicated table.
MASTER INTENSITY
0 - 5
No Light output
6 - 255
Light output linearly increase from minimum to maximum brightness
DURATION
0 - 255
Light time (versus dark time) linearly increases from shorter time
(2.5msec) to longer time (650msec)
See details in a following dedicated table.
IMPORTANT:
Duration Time must be lower than Rate Time (Period) for flashing.
If Duration Time is equal or greater than Rate Time (Period) the light
is continuously on.
STORMY CC C71091