beautypg.com

Cino SM5700 User Manual

Page 10

background image

F

u

z

z

y

S

c

a

n

O

E

M

S

c

a

n

M

o

d

u

le

P

ro

g

ra

m

m

in

g

M

a

n

u

a

l

5

Intelli Button

For normal operation, the Intelli Button of the scan module acts as a manual Trigger Switch. You can press the Intelli Button
to scan the corresponding barcode commands to configure your scan module with ease. Moreover, the useful Intelli Button
can help you to identify the best mounting position. Please refer to following descriptions for more details.

Optimize Your Installation

Once the mounting position for the scan module is determined, you may use the Intelli Button to optimize the mounting
position with ease. Please follow below procedures to use the Intelli Button.


Press and hold the Intelli Button for more than 5 seconds until the status indicator gives one green blink, then release the
button. The scan module will emit 2 short beeps and the power indicator will flash blue blink per 1 second to indicate the
force reading process is activated. The scan module will turn on the light source to scan barcodes continuously until the
whole process completed.


Keep the scan module to read the same barcode. The scan module will count the Good Read numbers, then output the
information of reading rate and refresh LED indications every 100 scans. The format of output message is listed below.

< Readout data >

:

< Reading rate (0 to 100) >

Meanwhile, both Status and OK/NG indicators provide the visible reading rate information as well. You may refer to the
table listed below for details.

Reading rate

POWER Indicator

STATUS Indicator

OK/NG Indicator

Beeper

100%

Steady Green

Steady Green

80 to 99%

Steady Red

Steady Green

50 to 79%

Steady Green

Steady Red

20 to 49%

Steady Orange

Steady Orange

0 to 19%

1 blue blink per 1 sec

Steady Red

Steady Red

One short beep

If the reading rate is not good enough, please adjust the reading angle and distance to get the optimum readability. If you
would like to exit the force reading process, please press the Intelli Button once again.

1.

If the scan module is unable to read any barcode during preset scan input time-out (default is 900ms), the scan module will

count it as a NG reading

2.

During force reading process, the OK/NG output signals will not be Performed.

This manual is related to the following products: