Temperature Limits
SECTION XII - Temperature Limits
Studies have indicated that dangerous
bacteria can form in the potable water
distribution system if certain minimum
water temperatures are not maintained.
For prevention of this, it is recommend-
ed that the Secondary Thermostat be set
as shown in Fig. 23 and maintained at
130ºF to 140ºF.
Setting Primary Thermostat Limit.
-
The Primary (Space Heating) Thermostat
located on the right side of the control
panel acts as the high limit during the
space heating function.
-
Set the thermostat knob as shown in
Fig. 22.
-
Maximum limit setting is 180ºF
To ensure proper function of the limits
the Primary Thermostat must be set
higher than the Secondary Thermostat.
Adjustment of Secondary Thermostat Limit
-
The Secondary (Domestic) Thermostat
located on left side of the control panel
maintains the minimum domestic water
storage temperature.
-
Set the thermostat knob as shown in
Fig. 23.
-
Maximum limit setting is 140ºF.
To adjust the thermostat settings:
-
Turn thermostat knob clockwise
to increase water temperature
-
Turn thermostat knob counter-
clockwise
to decrease water
temperature.
NOTICE
NOTICE
DANGER
Pha
se
III
-
Ph
a
se
III
- P
hase III
-
P
h
a
se
III
-
c
i
t
s
e
m
o
D
S
pa
ce
h
ea
tin
g
Temperature Up
Temperature Down
Temperature Indicator
Back
Plate
Knob
Fig. 23: Recommended Secondary
Thermostat Setting
Ph
a
se
III
-
Ph
ase III -
Ph
a
se
III
-
Pha
se
III
-
ci
ts
e
m
o
D
Space
heating
Temperature Up
Temperature Down
Temperature Indicator
Back
Plate
Knob
Fig. 22: Recommended Primary Thermostat
Setting