beautypg.com

External wiring – Delta F-25 User Manual

Page 39

background image

External Wiring

To ELITE

"Room Thermostat"

Snap Set

H

H

High Voltage

120

V.A.C.

24

V.A.C.

Room

Thermostat

Room

Thermostat

Zone 1

Zone 2

Additional zones

Additional zones may

be added as shown above

Transformer

(Power)

Zone

Valve

Zone Valve

* Isolation relay

1

C

34

4 Wire Zone Valve

Fig. 18: Multiple Zone Field Wiring Using Zone Valves

3 Wire Zone Valve

*Use isolation relay on 3-wire
zone valve with non-isolated
end switch. Transformer and
the ELITE control can burn out
if isolation relay is not used.

High Voltage

V.A.C.

24

V.A.C.

Room

Thermostat

Room

Thermostat

Zone 1

Zone 2

Additional zones

Additional zones may

be added as shown above

To ELITE

"Room Thermostat"

Snap Set

Transformer

(Power)

Zone

Valve

Zone Valve

C

1