beautypg.com

Baking compartment, Pallas back accessories, Problem possible reason solution – Austroflamm PallasBack User Manual

Page 10

background image

english

8

Pallas Back

5. Pallas Back Accessories

Baking compartment


The Pallas Back is different from the Pallas due to its fully functional baking compartment.

This baking compartment is heated from four sides (from left, right, behind and below). Hint: in order to achieve the
most even distribution of heat, the food to be heated should be turned after half of the baking time has been reached.

The temperature in the baking compartment is regulated by the amount of fuel used and the air control sliders (see
Fig. 2). The actual temperature can be read on the baking-compartment thermometer (accessory).

Clean the inside of the baking compartment, as you would do with other stove components (see above). Avoid fat-
containing vapours, because these leave deposits that are very difficult to clean off.



problem

possible reason

solution

door glass gets sooty too fast

generally: door glasses must be cleaned with
Austroflamm glass cleaner from time to time (depending
on the frequency of use)

bad chimney draught

contact your chimney sweep (elongate chimney/draught
metering)

incorrect use of the combustion air
supply lever

please operate air lever according to user's instructions
(if secondary air is closed, the door glass soots rather
fast)

wood logs are too large

keep to the max. fuel quantity according to user's
instruction

operating temperature was not
reached

more fuel, use dry wood (< 15 % residual moisture),
attend air regulation

stove does not get enough
combustion air

chimney draught not sufficient

contact your chimney sweep (elongate chimney/draught
metering)

stove is sooted inside

more fuel, use dry wood (< 15 % residual moisture),
attend air regulation

stove smells strongly and there
is smoke on the outside
surface

baking phase of the varnish

there may be some odour development during the first
operations

stove is dusty/dirty

cleaning before the heating season starts!

exhaust gas emission while
putting more wood on the fire
and during operation

inspect joints and seal up again if necessary

chimney draught no sufficient, flue
pipe connection leaky

check chimney draught, examine operating - for info
video follow:
http://www.austroflamm.com/de/Video/index.html

the stove door was opened before
the wood has burnt down to
embers

put more fuel wood into the combustion chamber only if
there are only embers left (no more visible flame)