STEP 4 - TURNING ON YOUR MONITOR

If there is a lost connection
between the 2 units
(refer to troubleshooting):

• The

Out-of-Range icon

will appear on the screen and
the Parent Unit will beep.

1) Press the Parent Unit ON/OFF button

to open and display normal mode.

2) Push and hold the Nursery Unit

left ‘wing’ button for 2 seconds.

1

When the Parent Unit is turned
ON and the Nursery Unit is OFF,
the Parent Unit will be searching
for connection with the Nursery
Unit. The Connection icon will scan
as the following cycle.

The LCD monitor has 30 seconds
timeout to go to power saving
mode (dimmer illumination).
Press any keys to wake up.

Temperature icon:
Indicates room temperature

Battery Level icon:
Indicates battery level

Empty

1/3 Full

2/3 Full

Full

Settings Icons: Access to settings

VOX icon: Indicates Vox function
is active (Voice activation)

ECO icon: Indicates ECO function
is active

Temperature Alarm icon: Indicates
Temperature Alarm is active

IMPORTANT ICONS

Sound icon: Indicates sound
is active

Sensor Pad icon: Indicates
the Movement Sensor is active

Pendulum icon: Indicates
the ‘TIC’ function is active

Level Bar: Indicates sound level
from Nursery Unit.

Connection icon: Indicates
the connection quality between
the Parent Unit and Nursery Unit.

Good connection

Fair connection

Poor connection

Out-of-Range

2

STEP 5 - TESTING AND GETTING TO KNOW YOUR MONITOR

The Angelcare

®

monitor can be used with the pre-program factory settings

or you can also customize your settings to your preference.

5.1 - SENSOR PAD

1) Press Sensor Pad icon to activate

or

deactivate movement mode.

1) Move your hand lightly on the mattress.

2) Remove your hand from the mattress.

After 15 seconds you will hear a
‘TIC’ pre-alarm sound, and 5 seconds
later the Movement Alarm will trigger.

3) Repeat by moving your hand lightly

in all four corners of the mattress.
Ensure the Nursery Unit Movement
Indicator is still flashing.

IF THE ALARM DOES NOT SOUND

• Avoid contact with crib while Sensor Pad is in operation.
• Place crib near a supporting wall.
• Adjust the Sensor Pad sensitivity level.

ON

OFF

1

2

TO ACTIVATE THE SENSOR PAD:

TO TEST THE SENSOR PAD:

MOVEMENT ALARM

• Alarm activates when no movement is detected by Sensor Pad for 20 seconds.
• Both the Parent Unit and Nursery Unit speakers will emit loud warning sound.
• Movement Alarm icon will show on the LCD screen.

1

When the movement mode is OFF
the ‘TIC’ mode is automatically set OFF.
This allows you to detect the

baby’s

sounds ONLY.

IMPORTANT
When in settings mode, sound
transmission between Parent and
Nursery Units will be temporarily
deactivated. ONLY the movement
alarm will remain active
(if function is activated).

NOTE: All changes
and adjustments made
in the settings mode will
not be activated unless
you confirm them by
pressing the Return icon.
A long beep will confirm
your modification.

15

14