ADLINK MCS-2040 User Manual
Page 50
50
MCS-2040
6. From the Intel AMT Configuration menu, select SOL/IDER/KVM. The SOL/IDER/KVM
screen appears, as shown below. Review the following settings:
Username and password
: Enabled (Recommended setting; default)
When enabled, this setting allows users and passwords to be added via the WebUI; if it is
disabled, only the administrator has MEBx remote access.
SOL
: Enabled (Recommended setting; default)
This setting enables or disables Serial-over-LAN (SOL) functionality.
IDER
: Enabled (Recommended setting; default)
This setting enables or disables IDE Redirection (IDE-R) functionality.
KVM Feature Selection
: Enabled (Recommended setting; default)
This setting enables or disables the keyboard/video/mouse feature.
Legacy Redirection Mode
: Enabled (Recommended setting; Enabled)
This setting allows the redirection feature to work with a pre-Intel AMT 6.0 SCS.
7. From the Intel AMT Configuration menu, select User Consent.
The User Consent screen appears, as shown below. Review the following settings:
User Opt-in
: NONE (Setting is user-dependent; recommended setting; NONE)
This setting is used to control remote KVM operating, the server must provide one-time
password for remote KVM.
Opt-in Configurable from Remote IT
: Enabled (Setting is user-dependent; Enabled by
default). This setting enables or disables a remote user’s ability to select user opt-in
policy. If set to disabled, only the local user can control the opt-in policy.