ADLINK LEC-BTS User Manual
Page 10
6
Overview
1.4.3
Power Specifications
Table 1-4 provides the power requirements for this module.
Operating configurations:
In-rush operating configuration - To be determined
Idle operating configuration - To be determined
*BIT = Burn-In-Test operating configuration - To be determined
1.4.4
Environmental Specifications
Table 1-5 provides the most efficient operating and storage condition ranges required for this
module.
1.4.5
Thermal/Cooling Requirements
The LEC-BTS is designed to operate at its maximum CPU speed and requires a thermal solu-
tion. ADLINK offers one cooling option described in Table 1-6.
Table 1-4: Power Supply Requirements
Parameter
E3815 (5W)
Characteristics
E3826 (7W)
Characteristics
E3845 (10W)
Characteristics
Input Type
Regulated DC voltage
Regulated DC voltage Regulated DC voltage
In-rush
Voltage & Current
Not yet measured
Not yet measured
Not yet measured
Typical Idle
Voltage & Current
Not yet measured
Not yet measured
Not yet measured
BIT*
Voltage & Current
Not yet measured
Not yet measured
Not yet measured
Table 1-5: Environmental Requirements
Parameter
Conditions
Temperature
Standard
0° to +60° C (+32° to +140° F)
Extended
–40° to +85° C (–40° to +185° F)
Storage
–55° to +85° C (–67° to +185° F)
Humidity
Operating
5% to 90% relative humidity, non-condensing
Non-operating
5% to 95% relative humidity, non-condensing
CAUTION: The overall system design must keep the ICs within their operating temperature
specifications.
Table 1-6: ADLINK Cooling Option
Cooling Option
Description
Heat Spreader
Provides a simple thermal platform on which to build a cooling solution.
CAUTION: The optional heat spreader plate requires another form of cooling, such as a fan.
A heat spreader plate is not a complete thermal solution for the LEC-BTS.