ADLINK cPCIS-2500 Series User Manual
Page 33

Power Supply Unit
• 27
Symbol: "★" OVP built-in; "@" Adjustable; "#" Remote sensing;
"≡" 3rd-wire Load Sharing; "=" Droop Current Sharing;
"☉" Installed with Or-ing diode; "▲" Magnetic Amplifier;
"●" Installed with Post-regulator; "■" Common Choke.
Remarks: Peak load sustainable for less than 60sec. with duty cycle <10%.
Max. load is the continuous operating load of each rail. Max. load
of each rail cannot be drawn from all outputs at the same time.
•
Over Load Protection: Fully protected against output overload or
short circuit. Typical 120% max. load.
•
Over Current Protection: Installed at each rail
•
Output Wattage: Typ. 250W continuous.
•
Output Connector: Positronic 47-pin PCIH47M400A1.
•
Line Regulation: Typ. 0.1%.
•
Load Regulation: Typ. ±1–2%.
•
Noise & Ripple: Typ. 1% peak to peak or 50mV, whichever is
greater.
•
OVP: Built-in at all outputs.
•
Adjustability: Available at VO1, 2 & 3.
•
Output Trim: Electrical trim available at VO1/VO2 [ADJ #].
•
Remote Sensing: Available at VO1, VO2 & VO3.
• Hot-Swap:
Available.
•
N+1 Redundancy: Installed with internal OR-ing diodes at all outputs
for N+1 redundancy operation.
• Current
Sharing:
Third-wire
current sharing at VO1,2 &3.
•
Power OK Signal: Available for all output.
•
Over Current Protection: Installed at each rail.
•
Overload Protection: Fully protected against output overload or
short circuit. Typical 120% max. load.