Input characteristics, Output characteristics – ADLINK cPCIS-2500 Series User Manual
Page 32

26
• Power Supply Unit
Input Characteristics
•
Input Voltage: Typ. 90-264VAC
•
Power Factor Correction: Meets Harmonic Correction IEC1000-3-2.
Power Factor typ. 0.95-0.97
•
Input Connector: Positronic 47-pin PCIH47M400A1
•
Input Frequency: 47-63Hz
•
Inrush Current: Less than 30A @ 230VAC
•
Input Current: 2.8A @115VAC / 1.4A @230VAC
•
Dielectric Withstand: Meets IEC950 regulation
•
EMI: Meets EN55022 / FCC Class A
•
Hold-up Time: 5mS after power fail signal
•
Remote ON/OFF: Available at [INH#] & [EN#] pins
•
Power Fail Signal: Available at [FAL#] pin
•
Status LED:
critical fault.
•
Thermal Protection (OTP): Installed NTC and thermostat for thermal
sensor at [DEG#] pin
•
Power OK: Installed at all outputs
•
Leakage Current: Typ. 0.5mA
Output Characteristics
Output Current (A)
Output
Voltage
MIN.
MAX.
TYP.
PEAK.
5V
MAIN +VO1
@ ★ # ≡ ☉
2.0 33.0 25.0
–
3.3V
AUX. +VO2
▲ @ ★ # ≡ ☉
0 33 18 –
12V
AUX. +VO3
▲ ≡ # ☉ ★ @
0 5.5 5.5 6
-12V
AUX. –VO4
● ☉ ★ ■ =
0 1 0.5
1.5