ADLINK aTCA-9300 User Manual
Page 29
29
Item
Sensor Name
Sensor
Address
Description
Lower Non-Recoverable Threshold = 2.97 Volts
(10)
+3.3V MG
(0x9)
Voltage Sensor.
Upper Non-Recoverable Threshold = 3.63 Volts
Upper Critical Threshold = 3.564 Volts
Upper Non-Critical Threshold = 3.498 Volts
Lower Non-Critical Threshold = 3.102 Volts
Lower Critical Threshold = 3.036 Volts
Lower Non-Recoverable Threshold = 2.97 Volts
(11)
+12V
(0xA)
Voltage Sensor.
Upper Non-Recoverable Threshold = 13.2 Volts
Upper Critical Threshold = 12.96 Volts
Upper Non-Critical Threshold = 12.72 Volts
Lower Non-Critical Threshold = 11.28 Volts
Lower Critical Threshold = 11.04 Volts
Lower Non-Recoverable Threshold = 10.8 Volts
(12)
PCH Temp
(0xB)
Temperature Sensor.
Upper Non-Recoverable Threshold = 95 degrees C
Upper Critical Threshold = 85 degrees C
Upper Non-Critical Threshold = 75 degrees C
Lower Non-Critical Threshold = 0 degrees C
Lower Critical Threshold = -5 degrees C
Lower Non-Recoverable Threshold = -10 degrees C
(13)
PSU1 Temp
(0xC)
Temperature Sensor.
Upper Non-Recoverable Threshold = 95 degrees C
Upper Critical Threshold = 85 degrees C
Upper Non-Critical Threshold = 75 degrees C
Lower Non-Critical Threshold = 0 degrees C
Lower Critical Threshold = -5 degrees C
Lower Non-Recoverable Threshold = -10 degrees C
(14)
CPU Thermal Temp
(0xD)
Temperature Sensor.
Upper Non-Recoverable Threshold = 95 degrees C
Upper Critical Threshold = 85 degrees C
Upper Non-Critical Threshold = 75 degrees C
Lower Non-Critical Threshold = -5 degrees C
Lower Critical Threshold = -10 degrees C
Lower Non-Recoverable Threshold = -15 degrees C
(15)
CPU Inner Temp
(0xE)
Temperature Sensor.
Upper Non-Recoverable Threshold = 95 degrees C
Upper Critical Threshold = 85 degrees C
Upper Non-Critical Threshold = 75 degrees C
Lower Non-Critical Threshold = -5 degrees C
Lower Critical Threshold = -10 degrees C
Lower Non-Recoverable Threshold = -15 degrees C