ADLINK PCI-C588/PCIe-C588/C584 User Manual
Page 35

Installation
• 29
1.
Now, you can follow the configuration dialog boxes to install the 
driver. 
2.
In the default condition, the TTY port is given name from “COM3”. 
User can specify the start “COM” port number in installation 
procedure. 
3.
We can install up to two same type serial communication cards in 
one NT system. 
4.
When you need to install two same type serial communication cards 
in one NT system, you must confirm to let one card’s jumper JP1 is 
ON while the other card’s jumper JP1 is OFF. 
5.
The card with jumper ON will have low COM port number. The card 
with jumper OFF will have higher COM port number follow the card 
with jumper ON. 
6.
If you install two same type serial communication cards with jumper 
ON or OFF simultaneously, we can not confirm that both cards will 
active properly. 
7.
If you install multiple cards in one NT system simultaneously, 
please confirm that the COM port number assigned do not overlap 
for different card. Or you may have improperly operation in your 
system. 
8.
For easy to maintain NT system’s COM port number, we suggest 
that you must set the jumper ON for the first card to be installed in 
NT system. 
9.
After you install the driver, you need to reboot your PC, then you 
can have more COM port available. 
10. If you had installed our NT driver in your system before, you might
remove this driver firstly, then you can install our new version driver. 
Or you might have some problem in your system. 