beautypg.com

ADLINK PXIS-2700 User Manual

Page 12

background image

6 ● Installation

2.3 System Monitoring

There are LEDs on the front panel for system monitoring, including
powers, temperature, and fans. Please refer to following for the detailed
meaning of display status on LEDs.

System Monitoring

ƒ

Power LED (Voltage : 3.3V, 5V, +12V, -12V)

o

Color:

Green

o

ON

while

supplied

ƒ Temperature

LED

o

Color:

Amber

o

ON for normal condition

o

Flashes if exceeds temperature

ƒ Fan

LED
o

Color:

Green

o

ON while normal fan speed

o

Flashes if abnormal fan speed

ƒ Alarm

LED

o

Color:

Red

o

ON while normal condition

o

Flashes if alarm occurs

The Alarm Buzzer beeps continuously if any alarm occurs. When the
Alarm Buzzer beeps, users can check the LED on the front panel to find
out which kind of alarm occurs.

There is a black button labeled Alarm RST near by the Alarm LED on the
front panel. When the Alarm LED flashes and the Alarm Buzzer continues
beeping, you can push Alarm RST button to stop beeping.

Users can further refer to Chapter 4 for Troubleshooting.

There is one Green LED on each power supply unit in the rear and the red
button between the power supply units is power RST. When the alarm
buzzer beeps and the power LED extinguishes, you can push power RST
button to stop beeping and refer to Chapter 4.5 to hot-swap the power
supply unit..