beautypg.com

9 d/a output register – ADLINK ACL-8112 Series User Manual

Page 48

background image

40

Registers

4.9 D/A

Output

Register

The D/A converter will convert the D/A output register data to an analog
signal. The register data at address Base + 4 and Base + 5 are used for D/A
channel 1and Base +6 and Base +7 for D/A channel 2.

Address : BASE + 4 & BASE + 5

Attribute: write only

Data Format: (for D/A Channel 1)

Bit

7

6

5

4

3

2

1

0

Base

+

4 DA7 DA6 DA5 DA4 DA3 DA2 DA1 DA0

Base

+

5 X X X X

DA11

DA10

DA9

DA8

Address : BASE + 6 & BASE + 7

Attribute: write only

Data Format: (for D/A Channel 2)

Bit

7

6

5

4

3

2

1

0

Base

+

6 DA7 DA6 DA5 DA4 DA3 DA2 DA1 DA0

Base

+

7 X X X X

DA11

DA10

DA9

DA8

DA0 is the LSB and DA11 is the MSB of the 12 bits data.
X: don't care

Note: The D/A registers are "double buffered" so that the D/A analog output

signals will not updated until the second (high) byte contains data or
written to. This will ensure a single step transition for a D/A conversion.