Operation Theory

35

Waveform Generation

This method is suitable for applications that need to generate
waveforms at a precise and fixed rate. Various programmable
counters will facilitate users to generate complex waveforms with
great flexibility.

Three event signals are involved in waveform generation: Start,
DAWR (DA WRite), and Stop. Refer to Table 4-6 for a brief sum-
mary of waveform generation events and their corresponding trig-
ger sources.

Event

Signal

Descriptions

Trigger Sources

Start

Start Waveform Generation pro-

cess.

Software Trigger

Ext. Digital Trigger

Analog Trigger

SSI Trigger

DAWR

Write data to the DAC on the falling

edges of DAWR.

Internal Update

External Update

SSI Update

Stop

Stop Waveform Generation

Software Trigger

Ext. Digital Trigger

Analog Trigger

Table 4-6: Trigger Signals and Corresponding Signal Sources