Introduction
Table 1-2: CN1/CN2 I/O Signal Description
1.7 Analog Input Signal Connection
The USB-1210 provides 4 truly differential analog input channels.
These four channels are simultaneous-sampling and support up to
2MS/s per channel. The analog signal can be converted to a digi-
tal value by the A/D converter. To avoid ground loops and obtain
more accurate measurement from the A/D conversion, it is impor-
tant to understand the type of signal source and how to connect
the signal in differential mode.
Signal Source Types
Floating
A floating signal source is not connected in any way to the
existing ground system. A device with an isolated output is a
floating signal source. This includes optical isolator outputs,
transformer outputs, and thermocouples.
Ground-Referenced
A ground-referenced signal is connected in some way to the
existing ground system. That is, the signal source is already
connected to a common ground point with respect to the
USB-1210, assuming that the computer is connected to the
same power system. Non-isolated outputs of instruments and
CGND
N/A
None Chassis ground
GPI<0..7>
IGND
I
Function Input <0..7>
(see Section 3.1.5: Programmable
Function I/O)
GPO<0..3>
IGND
O
Function Output <0..3>
(see Section 3.1.5: Programmable
Function I/O)
CONV
IGND
I
External A/D conversion clock
AITG
IGND
I
Digital trigger for analog input
NC
NC
NC
No connection
Signal
Reference I/O