LUBRICATION:

CHASSIS:

(5) grease zerks used

LOCATIONS:

(1) each front wheel caster tube

(1) each mower deck hub

SERVICE INTERVALS:

Every 50 hours of operation

RECOMMENDED GREASE: Name brand wheel bearing or

multi-purpose grease. Once

per season or 50 hours of

operation (3 pumps each).

Note: Adequate lubrication of the caster tubes and mower deck

hubs will help dispel moisture from within the bearing

retention areas. Bearings are of a sealed variety.

CARE AND MAINTENANCE

FUEL SHUT OFF VALVE:

The fuel shut off valve is located at the bottom rear of the

fuel tank.

Always turn the valve to the “OFF” position when the mower

is stored or not in use.