Step-ladder mode – Datalogic Scanning DS1500 User Manual
Page 43

READING FEATURES
3
3.2.1 Step-Ladder
Mode
If scanning is perpendicular to the code motion direction (Figure 23), the number of
effective scans performed by the reader is given by the following formula:
SN = [(LH/LS) * SS] – 2
Where: SN = number of effective scans
LH = label height (in mm)
LS = label movement speed
in
(mm/s)
SS = number of scans per second
Direction of code
movement at LS speed
LH
DS1500
Laser beam
Figure 23 - "Step-Ladder" Scanning Mode
For example, the DS1500 (1200 scans/sec.) for a 20 mm high code moving at 1200
mm/s performs:
[(20/1200) * 1200] - 2 = 18 effective scans.
31