Q-See QSZ515D User Manual
Page 4

Problem
Possible reason
Solution
No movement and ima
ge at power-on
1.Check the connection of
C power input
2.Turn off power and check t
he transformer
1.Check the power
connection, make sure the soc
ket is well connected
2.Make sure the power outlet is
working
Power-on shows
mage,
but the controlle
r doesnot work
1. DIP switch setting is incorrect
2.RS485 interface is not connec
ted or is not connected corre
ctly
3.There is a problem with the
S485 line
1. Refer to setup instructi
ons, re-set the DIP switches.
2.Check RS485 interface,
sure the wires are well connect
ed and in the proper slots
3.Refer to the Appendix: RS485
Blurred Image
Ball case is dirty
Clean the ball case
2.
2. Setting of DIP Switches
The internal black case has 8 DIP switches. 8,7,6,5,4,3,2,1 are for Addres
s setting, while 10,9 are for Communication Baud Rate.
In the following table, tag “1” for DIP switch “ON”; tag “0” for DIP switch “off”.
a) Setting Baud Rate
Baud Rate
Switch #
(SW2)
Baud Rate
Switch #
(SW2)
BIT 10 9
BIT 10 9
2400bps
0 1
1200bps
1 1
4800bps
1 0
9600bps
0 0
b) b) Setting Address Code
In a system, decoder includes intelligent speed dome camera and common de
coder. No repeating address codes exist. As you see in the table, “1” for “O
N”, “0” for “OFF”
Address
Address Switch (8
Address
Address Switch
(8
Code
1 2 3 4 5 6 7 8
Code
1 2 3 4 5 6 7 8
1
1 0 0 0 0 0 0 0
33
1 0 0 0 0 1 0 0
2
0 1 0 0 0 0 0 0
34
0 1 0 0 0 1 0 0
3
1 1 0 0 0 0 0 0
35
1 1 0 0 0 1 0 0
4
0 0 1 0 0 0 0 0
36
0 0 1 0 0 1 0 0
5
1 0 1 0 0 0 0 0
37
1 0 1 0 0 1 0 0
6
0 1 1 0 0 0 0 0
38
0 1 1 0 0 1 0 0
7
1 1 1 0 0 0 0 0
39
1 1 1 0 0 1 0 0
8
0 0 0 1 0 0 0 0
40
0 0 0 1 0 1 0 0
9
1 0 0 1 0 0 0 0
41
1 0 0 1 0 1 0 0
10
0 1 0 1 0 0 0 0
42
0 1 0 1 0 1 0 0
11
1 1 0 1 0 0 0 0
43
1 1 0 1 0 1 0 0
12
0 0 1 1 0 0 0 0
44
0 0 1 1 0 1 0 0
13
1 0 1 1 0 0 0 0
45
1 0 1 1 0 1 0 0
14
0 1 1 1 0 0 0 0
46
0 1 1 1 0 1 0 0
15
1 1 1 1 0 0 0 0
47
1 1 1 1 0 1 0 0
16
0 0 0 0 1 0 0 0
48
0 0 0 0 1 1 0 0
17
1 0 0 0 1 0 0 0
49
1 0 0 0 1 1 0 0
18
0 1 0 0 1 0 0 0
50
0 1 0 0 1 1 0 0
19
1 1 0 0 1 0 0 0
51
1 1 0 0 1 1 0 0
20
0 0 1 0 1 0 0 0
52
0 0 1 0 1 1 0 0
21
1 0 1 0 1 0 0 0
53
1 0 1 0 1 1 0 0
22
0 1 1 0 1 0 0 0
54
0 1 1 0 1 1 0 0
23
1 1 1 0 1 0 0 0
55
1 1 1 0 1 1 0 0
24
0 0 0 1 1 0 0 0
56
0 0 0 1 1 1 0 0
25
1 0 0 1 1 0 0 0
57
1 0 0 1 1 1 0 0
26
0 1 0 1 1 0 0 0
58
0 1 0 1 1 1 0 0
27
1 1 0 1 1 0 0 0
59
1 1 0 1 1 1 0 0
28
0 0 1 1 1 0 0 0
60
0 0 1 1 1 1 0 0
29
1 0 1 1 1 0 0 0
61
1 0 1 1 1 1 0 0
30
0 1 1 1 1 0 0 0
62
0 1 1 1 1 1 0 0
31
1 1 1 1 1 0 0 0
··
········
32
0 0 0 0 0 1 0 0
255
1 1 1 1 1 1 1 1
Part 5 PELCO-D Protocol
Data Form
:1 beginning position, 10 pieces for data, 1 ending position, invalid
checking point