beautypg.com

Part 3 extended function, Part 4 appendix – Q-See QSZ515D User Manual

Page 3

background image

5. Large square of monotonous object, like a wall;

6. The object is too dark or vague;

7. The targeted picture is too small

3.

3. Surveillance function

a) Set & Transfer the preset points

The function of preset positions is, temporarily storing such

location parameters as horizontal angle / inclination / lens’ focus in a mem

ory and transferring them whenever they’re needed. User

can quickly transfer the preset positions via the keyboard, remote or some

thing else such as PC software. The speed dome

supports 127 preset points.

b) Automatic Cruise

Automatic Cruise is an internal set function, which inserts the

points and sets up the automatic cruise among preset positions by program

ming them beforehand in the cruise lists. The cruise order and pausing timi

ng can be programmed and one cruise route can store 8 points and time

s.

c) Auto Scanning

Cameras can level scan back and forth among the left & right limits at

the set speed via the keyboard and menu settings using the left and righ

t limits setup beforehand.

d) Power-off Protection

When a planned or unplanned power-off happens, the camera

will automatically preserve the movement state before the

power-off. When the power returns, the camera will auto-recover the previ

ous stored movement.

Part 3 Extended Function

This section describes the extended function and common principles of the a

ll in one intelligent dome camera. Different systematical

platforms have different methods. In some cases, special

requirements & operational methods could exist, subject to

systematical manufacturer’s manual.

1.

1. Set the scanning

The speed dome can be set in two fixed locations and scan back and fort

h at the set speed. Set #126 for linear scanning. Set #xxx preset position,

xxx is the scanning speed (1-50 adjustable), after that, move the rod, the

image would move to the beginning locations. Set #127 as scanning

beginning location, moves the image to the ending location and set #1

28 as the ending scan location.

Example 1

:Scan setting at the speed of 1s around.

Setting Method

1. Set #126 preset position.

2. Set #30 as speed index.

3. Move the rod and adjust the image as the scanning one.

4. Set #127 as the beginning location.

5. Move the rod and adjust the image to the scanning ending location.

6. Set #128 as the ending location

Example 2

:Scan setting at the speed of 50s around.

Setting Method

7. Set #126 preset position.

8. Set #50 as speed index.

9. Move the rod and adjust the image as the scanning one.

10. Set #127 as the beginning location.

11. Move the rod

12. Set #128 as the ending location

2.

Transfer the cruise group

Transfer #101-102 preset point; relatively start #1-2 cruise groups. For ex

ample

:Start #1 cruise group.

Method: Transfer #101 preset position.

3.

Start the linear scanning

Transfer #128 preset position.

4.

Start auto-scanning

Transfer #125 preset position or press auto-start button.

36

0° Auto-scanning back and forth. The speed is fixed internally.

Part 4 Appendix

1.

1. Clearing of fault