10

Refrigerator Operation

Water Filter Performance Data

Substance Reduction

Aesthetic Effects

NSF Reduction

Requirements

Average

Influent

Influent Challenge

Concentration

Maximum

Effluent

Average

Effluent

Minimum %

Reduction

Average %

Reduction

Chlorine Taste/Odor

Particulate Class I*

50% reduction

85% reduction

1.88 mg/L

5,700,000 #/mL

2.0 mg/L ± 10% At least

10,000 particles/mL

0.06 mg/L

69,000 #/mL**

0.05 mg/L

30,583 #/mL

96.84

98.94

>97.26

99.52

Contaminant

Reduction

NSF Reduction

Requirements

Average

Influent

Influent Challenge

Concentration

Maximum

Effluent

Average

Effluent

Minimum %

Reduction

Average %

Reduction

Lead: @ pH 6.5

Lead: @ pH 8.5

0.010 mg/L

0.010 mg/L

0.153 mg/L†

0.150 mg/L†

0.15 mg/L ± 10%

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

< 0.001mg/L

< 0.001mg/L

>99.29%

>99.29%

>99.35%

>99.33%

Mercury: @ pH 6.5

Mercury: @ pH 8.5

0.002 mg/L

0.002 mg/L

0.006 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.006 mg/L ± 10%

0.0005 mg/L

0.0015 mg/L

0.0003 mg/L

0.0008 mg/L

90.91

75.93

95.70

86.22

Toxaphene

0.003 mg/L

0.015 mg/L

0.15 ± 10%

< 0.001mg/L

< 0.001mg/L

91.67%

92.97%

Atrazine

0.003 mg/L

0.009mg/L

0.009 mg/L ± 10%

< 0.002mg/L

< 0.002mg/L

75.31%

76.99%

Asbestos

99%

155 MF/L

107 to 108 fibers/L††

< 1 MF/L

< 1 MF/L

>99.99%

>99.99%

Live Cysts‡

Turbidity

>99.95%

0.5 NTU

166,500 #/L

10.7 NTU

50,000/L min.

11 ± 1 NTU

< 1 #/L‡

0.49 NTU

< 1 #/L‡

0.31 NTU

>99.99%

95.2

>99.99

>97.09%

Lindane

0.0002 mg/L

0.0002 mg/L

0.002 ± 10%

< 0.0001mg/L

0.000mg/L

96.50%

>98.72%

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).

*

Class I particle size: >0.5 to <1 um

**

Test requirement is at least 100,000 particles/mL of AC Fine Test Dust

These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions

††

Fibers greater than 10 um in length

Based on the use of Cryptosporidium parvum oocysts

Specifications

Water Supply:

City or well

Service Flow Rate:

.78 gpm (2.9 L/min) @ 60 psi

Water Pressure:

35 - 120 psi (241 - 827 kPa)

Water Temperature:

33° - 100°F (1° - 38°C)

It is essential that operational, maintenance and filter replacement

requirements be carried out for the product to perform as adver-

tised.
The filter monitor system measures the amount of water that

passes through the filter and alerts you to replace the filter. When

90% of the filter’s rated life is used, the yellow (Order) light comes

on. When 100% of the filter’s rated life is used, the red (Replace)

light comes on, and it is recommended that you replace the filter.

For models without filter status lights, replace the filter every 6

months. Use Dacor replacement cartridge AFF3.
This product is for cold water use only.

Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or after

the system. Systems certified for cyst reduction may be used

on disinfected waters that may contain filterable cysts.

This system has been tested according to ANSI/NSF 42 and 53

for reduction of the substances listed above. The concentration

of the indicated substances in water entering the system was

reduced to a concentration less than or equal to the permissible

limit for water leaving the system, as specified in ANSI/NSF 42

and 53.
® NSF is a registered trademark of NSF International.

System tested and certified by NSF International against NSF/ANSI Std 42 for the reduction of Chlorine Taste and Odor,

Particulate Class I and against NSF/ANSI 53 for the reduction of Cysts, Turbidity, Asbestos, Mercury, Lead, Benzene,

p-Diclorobenzene, Carbofuran