Dacor IF42BNDB User Manual
Planning guide, 42” & 48” wide built-in refrigerator
PLANNING
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
11.2
42” & 48” wide
built-In refrigerator
Ef42bDCb, Ef42bNDb, If42bDCb, If42bNDb,
Ef48bDCb, Ef48bNDb, If48bDCb, If48bNDb
112905
1/3
Model
Rough-In Width “A”
42-Inch
41 1/2”” (1054mm)
48-Inch
47 1/2”” (1207mm)
D
oor
s
winG
D
imEnsions
The area to the left and the right of the appliance must permit
both doors to open to a minimum of 90°. Allow a minimum of 2
1/2” (64mm) space between the side of the refrigerator doors and
a corner wall.
NOTE: More clearance may be required if using an overlay panel
or custom handles.
p
roDuct
D
imEnsions
◊
The depth from the front of the top grill (w/o decorator panel)
to the back of the refrigerator chassis is 25 1/4” (641mm).
◊
The depth from the rear of the top grill to the back of the
refrigerator chassis is 23 13/16” (605mm).
◊
The power cord is 40” (1016mm) long.
◊
The height from the top of the top grill to floor with the
leveling legs in the down position is 83 3/8” (2118mm)
◊
The height from the top of the top grill to floor with the
leveling legs in the fully extended position is 84 5/8”
(2149mm)
◊
The chassis width from the chassis edge to the chassis edge
for 42-inch is model 41 1/4” (1048mm), 48-inch is model 47
1/4” (1200mm).
◊
The overall width from the trim edge to the trim edge for 42-
inch model is 42 1/16” (1068mm), 48-inch model is 48 1/16”
(1221mm).
E
lEctrical
r
EquirEmEnts
A 115VAC, 60 Hz, 15 Amp circuit breaker and electrical supply are
required. A separate dedicated non-GFCI circuit, servicing only
this appliance, is required.
Your Dacor
®
Built-In refrigerator is equipped with a 40” (1016mm)
3-prong grounded power cord, which must be plugged into a
3-prong grounding-type non-GFCI wall receptacle. Follow the
National Electrical Code and local codes and ordinances when
installing the receptacle. See “Rough-In Dimensions” for location
of the electrical supply.
IMPORTANT: A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
◊
All installations must meet local plumbing code
requirements.
◊
Connect to 1/4” (6mm) copper line to the house cold fresh
water supply.
◊
Use a shut off valve between the refrigerator and supply.
The shut off valve should be a drilled saddle valve.
◊
Do not use a self-tapping valve which reduces water flow
and clogs more easily.
◊
Route the water line within 3-1/2” (89mm) of the rear wall
and no higher than 3” (76mm) from the floor.
◊
Allow a minimum of 24” (610mm) dimeter service loop of
copper tubing outside the wall or floor for easy connection to
the water supply.
Cold water supply
Connect the ice maker to a cold water line with water pressure
between 30 and 120 PSI. If you have any questions about your
water pressure, call your utility company.
IMPORTANT:
◊
In homes with a Reverse Osmosis water treatment system,
remove the water inlet connector from the “yellow” valve
and attached to the “blue” valve. Make sure the water filter
bypass plug is in place.
w
atEr
s
upply
r
EquirEmEnts
7”
4”
2”
6”
3”
75 1/2”
“A”
83 3/4”
Water Supply
Electrical
24”