beautypg.com

Installation – Desa VsGF28PTF User Manual

Page 9

background image

www.desatech.com

119303-01A

9

WARNING: These models have

a three-prong, grounded electrical

plug. This plug helps protect you

against electrical shock. Only con-

nect plug to a properly grounded,

three-prong receptacle. Do not cut

or remove the grounding prong

from this plug.

CAUTION: This fireplace cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to fireplace. Installing

fireplace next to vinyl or cloth

wall coverings or operating

heater where impurities (such

as, but not limited, to tobacco

smoke, aromatic candles, clean-

ing fluids, oil or kerosene lamps,

etc.) in the air exist, may discolor

walls or cause odors.

Note:

Your fireplace is designed to be used in zero

clearance installations. Wall or framing material

can be placed directly against any exterior surface

on the rear, sides or top of your fireplace, except

where standoff spacers are integrally attached. If

standoff spacers are attached to your fireplace,

these spacers can be placed directly against wall

or framing materials.

Use the dimensions shown for rough openings to

create the easiest installation. See Built-In Fire-

place Installation, page 11.
IMPORTANT:

Vent-free heaters add moisture to

the air. Although this is beneficial, installing fire-

place in rooms without enough ventilation air may

cause mildew to form from too much moisture. See

Air for Combustion and Ventilation, page 6.
IMPORTANT:

Make sure the fireplace is level. If

fireplace is not level, log set will not work properly.
CHECK GAS TYPE

Use the correct gas type (natural or propane/LP)

for your fireplace. If your gas supply is not cor-

rect, do not install fireplace. Call dealer where you

bought fireplace for proper type fireplace.

This appliance is only for use

with the type of gas indicated on

the rating plate. This appliance

is not convertible for use with

other gases.

WARNING: This appliance is

equipped for natural or propane/

LP gas. Field conversion is not

permitted.

ELECTRICAL HOOKUP

This fireplace has a blower assembly with an

electrical cord. The electrical cord is five feet in

length. You must locate fireplace within reach of

120-volt grounded electrical outlet. If not, you

must install an electrical outlet within reach of

fireplace power cord. The GA3555 outlet acces-

sory may be used for built-in installation when a

blower is installed.

INSTALLING HOOD

Install hood to rail already installed in fireplace

as shown in Figure 5. Use 3 Phillips screws

provided.

insTallaTion

Continued

Figure 5 - Installing Hood

Screw

Hood

Rail

ASSEMBLING AND ATTACHING
OPTIONAL PERIMETER TRIM
(Included with Mantel Accessory)

IMPORTANT:

If you are recessing the firebox in

a wall, do not attach trim at this time. See Built-In

Fireplace Installation, page 11.
Note:

These instructions are for assembling and

attaching trim to fireplace.

1. Remove packaging from three pieces of trim.

2. Locate four screws, two adjusting plates

with set screws, and two shims in the hard-

ware packet.

3. Align shim under adjusting plate as shown in

Figure 6, page 10.

This manual is related to the following products: