LIGHTING

INSTRUCTIONS

WARNING: You must operate

this fireplace with the fireplace

screen in place. Make sure fire-

place screen is installed before

running fireplace.

NOTICE: During initial operation

of new fireplace, burning logs

will give off a paper-burning

smell. Orange flame will also be

present. Open window to vent

smell. Operate fireplace on HI

position to burn off odor. This

will only last a few hours.

1. STOP! Read the safety information, page 17.

2. Make sure equipment shutoff valve is fully

open.

3. Turn control knob clockwise

to the

OFF position (see Figure 27).

4. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information, page 17. If you don’t

smell gas, go to the next step.

5. Turn control knob counterclockwise

to the PILOT position. Press in control

knob for five (5) seconds (see Figure 27).

Note: If running fireplace for first time,

there will be air in gas line. You may need

to press in control knob for 30 seconds or

longer. This will allow air to bleed from the

gas system.

6. Continue pressing control knob in. Press

and release ignitor button. This will light

pilot. The pilot is attached to the front

burner. If needed, keep pressing ignitor

button until pilot lights.

Figure 27 - Control Knob and Ignitor

Button Location

Ignitor Button

Control
Knob

oPeraTinG FirePlace

Continued

Note: If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure, page 19.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

Note: If pilot goes out, repeat steps 3

through 7. This fireplace has a safety inter-

lock system. Wait one (1) minute for system

to reset before lighting pilot again.

• If control knob does not pop out when

released, contact a qualified service person

or gas supplier for repairs.

8. Turn control knob counterclockwise

to desired heating level. The burners should

light. Set control knob to any heat level

between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Figure 28 - Pilot

Ignitor
Electrode

Pilot Burner

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

Turn control knob clockwise

to the OFF

position.
Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

THERMOSTAT CONTROL

OPERATION

You can set the thermostat control knob to any

comfort level between HI and LO. The thermo-

stat will gradually modulate the heat output

and flame height from higher to lower settings

or pilot, in order to maintain the comfort level

you select. The ideal comfort setting will vary

by household depending upon the amount of

space to be heated, the output of the central

heating system, etc.
Note:

Selecting the HI setting will cause the

burner to remain on without modulating down

in most cases.