2 technician commands, 1 reset main control board – DoorKing 1820 User Manual
Page 50

4.2 Technician
Commands
The following commands should be used by trained technicians only and are designed for trouble
shooting purposes.
4.2.1 Reset Main Control Board
This programming sequence will reset the 1885 main control board to the factory default values. This
function will take about 5 minutes to complete.
1. Take the doorman telephone off hook.
2. Press *91 and enter the four-digit MASTER CODE _ _ _ _ (beep).
3. Enter 9 9 9 9 then press * (beep).
4. Hang up the doorman telephone to end the programming session.
Function Section Default
Description
54
3.1.2
0
1882 Relay boards
07 3.1.3 0011
Highest
available
relay
41
3.1.5
1234567890 Caller ID default number
08
3.1.6
60
Talk time in seconds
04
3.1.7
5,2
5 rings, double ring
05 3.1.8 98
76
Relay
tone
numbers
03 3.1.9 01 Relay
strike
time
13
3.2.2
1
Programmable directory codes OFF
09 3.3.1 F
mmed
FFF
Outside
line
access code not progra
51
3.5.1
0
Do not disturb OFF
45
3.6.1
0
Call forwarding OFF
52
3.7.1
0
Virtual doorman OFF
53
3.7.2
01
strike time
Virtual doorman relay
32
3.8.1
0
Call-Down OFF system wide
34
3.8.2
1
N, call-down timer OFF
,0
Doorman call-down control O
35
3.8.3
30
Call-down disable timer in seconds
37
3.8.4
7
Resident direct connect call-down number
38
3.8.5
8
Resident programming number
12
4.1.1
1
Lobby panel ON
42
4.2.3
05
t time in seconds
Touch-tone detec
Page
50
1820-065-B-2-06