oPeRaTIoN
Continued
Shut Off Procedure
To save battery power, press
to turn main
gas to pilot gas. Press the OFF button to
shut off the device including pilot flame. The
device can be shut off with ON/OFF switch,
thus disabling remote hand set.
Setting Display ( °C/24h and °F /12h)
Press and hold OFF and
until display
changes from °F (and 12 hour clock) to °C
(and 24 hour clock) or vice versa.
Setting The Time
• After connecting battery or by simultane-
ously pressing
and
the display will
start to flash. You are in the set mode.
• From SET mode press
to set the hour
and
to set the minute.
• Wait or press OFF to return to manual
mode.
Battery Replacement
Remote handset battery needs to be changed
when LED is dim. Battery life expectancy is
2 to 3 years. Replacement is recommended
at the beginning of heating season. Battery
needs to be changed when acoustic error
message appears during ignition (see Identify-
ing Error Signals from Receiver, page 24).
Changing Mode of Operation
• Press the SET button quickly to change the
mode of operation in the following order:
MAN,
TEMP, TEMP, TIMER.
• Manual flame height adjustment (MAN ap-
pears on display): Press
to turn on the
fire (main burner) or to increase flame height.
Press
to decrease flame or to go down
to pilot only. The receiver acknowledges the
transmission with an acoustic signal.
• The day time temperature mode ( TEMP
appears on display): The sensor in the
transmitter measures room temperature.
The controller compares the room tem-
perature with set temperature and sends
a signal to the receiver to turn gas valve
motor up or down, to adjust flame height
accordingly.
• The nighttime setback temperature (
TEMP appears on display): The sensor in
the transmitter measures the temperature
and adjusts it according to the nighttime
setback temperature. There is a bigger
temperature differential during this cycle.
• Timer: The timer mode (TIMER) operates
much like the temperature mode above.
The timer setting allows you to set specific
times for on and off. (There are 2 burner
on and 2 burner off cycles every 24 hours.)
If the reading for the nighttime temp. is
"– – –", the motor will turn off the valve to
standby pilot position and wait for the next
burner on cycle. This display shows the
setting temperature every 30 seconds.
Setting Temperature
• Select the desired mode of operation
(day or night) by pressing the SET button
briefly.
• Hold SET button until display flashes.
• Set temperature with the
or
(40°F is
the minimum temperature).
• Wait or press OFF to go to temperature
control mode.
• If temperature control in moon times
should be off (lower battery consumption),
decrease night temperature until "– – –"
appears on display.
Set Timer
• Switch to timer mode by pressing the SET
button briefly.
• Press the SET button until P1
flashes.
• Set hours with
and minutes with
.
• Press SET briefly for the next burner cycle
time.
• If all 4 times are set, pressing the OFF but-
ton or waiting will complete programming.
Shutting Off Heater
Press OFF button on remote control to switch
off main gas and pilot gas.
Shutting Off Burner Only (pilot stays lit)
Press
to decrease the flame height and
shut off main burner.
SET
OFF
STAND
BY
Figure 18 - Control Panel for Hand-Held
Remote