beautypg.com

Operation – Design Dynamics PFS VF-18P-MHD User Manual

Page 16

background image

www.fmiproducts.com

116986-01H

16

WARNING: Burner will come

on automatically within one min-

ute after pilot burner is lighted.

6. Press the buttons

and

at the same

time. A short acoustic signal confirms start
sequence has begun.

Further short acoustic signals (0.2 sec.,
1 Hz) indicate the ignition process until it
is completed and main gas flows. If pilot is
already lit, motor will turn on (max. flame
height) while buttons are pressed down. If
pilot does not light, see Troubleshooting,
page 21.

7. Press

to turn on main burner and

increase flame height. Press

to de-

crease flame height and shut off main
burner.

8. Short tapping of either button allows

incremental change in flame height.

9. Press OFF button to switch off main gas

and pilot gas.

10. To leave pilot lit and shut off burners only,

press

to decrease flame height and

shut off main burner.

FUNCTIONS OF

REMOTE CONTROL

Battery
• After the charged battery has been correctly

installed, the remote hand set is ready for
operations.

• Remove the battery if the remote handset

will not be used more than one year.

Changing Code
The control is radio frequency operated. A
code (chosen from among 4,000 available
codes) is preset for all valves, but can be
changed if required (15 additional codes avail-
able). Change DIP switch position. (The DIP
switch is located inside the hand held control
at the top of the battery compartment.) Then
press the receiver's reset button on the bottom
of the receiver module until you hear a second
(longer) signal. When pressing the

button

on the remote handset in the following 20 sec.,
the receiver learns the new code.

oPeRaTIoN

Continued

REMOTE LIGHTING

INSTRUCTIONS

WARNING:

• If fireplace has glass doors,

never operate this heater with

glass doors closed. If you op-

erate heater with doors closed,

heat buildup inside fireplace

will cause glass to burst. Make

sure there are no obstructions

across openings of fireplace.

• You must operate this heater

with a fireplace screen in

place. Make sure fireplace

screen is closed before run-

ning heater.

NOTICE: During initial operation

of new heater, burning logs will

give off a paper-burning smell.

Orange flame will also be pres-

ent. Open damper or window to

vent smell. This will only last a

few hours.

CAUTION: A mild gas flash

within 10 seconds is normal

during shutdown of this heater.

Remain clear of the hearth area

for the entire shutdown process

to avoid possible injury.

1. STOP! Read the safety information,

page 15.

2. Make sure equipment shutoff valve is fully

open.

3. Turn motor knob clockwise

to the

OFF position.

4. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the
floor. If you smell gas, STOP! Follow “B”
in the safety information, column 1. If you
don’t smell gas, go to the next step.

5. Make sure ON/OFF switch is in "–" (ON)

position.

This manual is related to the following products: