OPERATING HEATER

Continued

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 6 under Lighting

Instructions, pages 22 and 23.

2. Depress control knob and light pilot with

match.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow steps 9 through

11, Lighting Instructions, page 23.

OPTIONAL HAND-HELD

REMOTE OPERATION

Note:

All remote control accessories must be

purchased separately (see Accessories, page

42). Follow instructions included with the

remote control.

NOTICE: You must light the pilot

before using the hand-held re-

mote control unit. See Lighting

Instructions on page 22.

After lighting, let pilot flame burn for about

one minute. Turn control knob to ON posi-

tion. Adjust flame adjustment knob anywhere

between HI and LO. Slide the selector switch to

the REMOTE position (see Figure 33). Note:

The burner may light if hand-held remote was

on when selector switch was last turned off.

You can now turn the burner on and off with

the hand-held remote control unit.
IMPORTANT:

Do not leave the selector switch

in the REMOTE or ON position when the pilot

is not lit. This will drain the battery.

ON/OFF SERIES (MODEL HRC100)

Hold the control button on the hand-held remote

until burner turns on. Hold the control button

again until burner turns off (see Figure 34).

TO LOCK

press both buttons on hand-held

remote control until light stops flashing. Hand-

held remote control is now locked. If the fire is

on it will be turned off automatically. In the

locked state, the light will not light up when

any button is pressed.
TO UNLOCK

press both buttons together

on hand-held remote control until the light

stops flashing. The hand-held remote is now

unlocked.

Figure 34 - On/Off Hand-Held Remote

Control Unit

Figure 35 - Thermostat Hand-Held

Remote Control Unit

Figure 33 - Setting the Selector switch,

Control Knob and Flame Adjustment

Knob for Remote Operation

O

FF

P

ILO

T

LO

IH

ON
OFF
REMOTE

O

N

Selector Toggle Switch (Optional
Hand-Held Remote Control)

Control Knob in
On Position

Flame Adjustment
Knob

Control
Button

Indicator
Light

LOCK

MANU

AUTO

ºC/ºF

TEMP

POWER

ROOM
TEMP

SET
TEMP

AUTO

Turns
Hand-Held
Remote On
or Off and
Allows You
to Choose
the Manual
Setting

Selects
AUTO
Mode

°C/°F Mode
Button

Locks
System to
Prevent
Accidental
Ignition

Turns
Burners
On or
Off

Increases
or Decreases Room
Temperature in
AUTO Mode

Digital Display Shows
Temperature and Settings

THERMOSTAT SERIES (MODEL
HRC200)

The hand-held remote can be operated using

either the manual mode (MANU) or thermo-

static mode (AUTO) (see Figure 35). To select

Fahrenheit/Centigrade mode display, carefully

press the ˚C/˚F mode button with the end of a

paper clip or similar blunt object.