5. Turn control knob counterclockwise

to the PILOT position. Press in control

knob for five (5) seconds (see Figure 28).

Note: You may be running this heater for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

6. With control knob pressed in, press and

release ignitor button. This will light pilot.

The pilot is attached to the front burner. If

needed, keep pressing ignitor button until

pilot lights.

Note: If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop out when

released, contact a qualified service person

or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3

through 7. This heater has a safety interlock

system. Wait one (1) minute for system to

reset before lighting pilot again.

8. Turn control knob counterclockwise

to desired heating level. The burners should

light. Set control knob to any heat level

between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

OPERATING HEATER

Continued

Figure 28 - Control Knob and Ignitor

Button Location

Figure 29 - Pilot

Control Knob

Ignitor Button

Ignitor Electrode

Thermocouple

Pilot
Burner

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise

to the

OFF position.
Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any

comfort level between HI and LO. The ther-

mostat will gradually modulate the heat output

and flame height from higher to lower settings

or pilot, in order to maintain the comfort level

you select. The ideal comfort setting will vary

by household depending upon the amount of

space to be heated, the output of the central

heating system, etc.
Note:

Selecting the HI setting with the control

knob will cause the burner to remain fully on,

without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting

Instructions, page 20 .

2. Depress control knob and light pilot with

match.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow step 8 under

Lighting Instructions, column 1.