Wall thermostat shutdown blower, Wall thermostat, Shutdown – Drolet Ultra Flame DG05437/DG05447 User Manual
Page 7: Blower
ULTRA FLAME DV “0” Clearance Fireplace
• Press gas control knob in and hold. Immediately push the red igniter button repeatedly until
pilot flame ignites. Continue holding in the control knob for 5 to 10 seconds, then release it.
If the pilot flame goes out, repeat this step.
•
Push and turn gas control knob counterclockwise to the "on" position.
CAUTION: This fireplace is hot while in operation. Do not touch. Keep children, clothing
and flammable materials away.
WALL THERMOSTAT
To operate your ULTRA FLAME using the wall thermostat, follow the lighting procedure and
set the gas control to the ON position. Simply set your wall thermostat to a comfortable
temperature and the fireplace will do the rest.
During the heating season, you do not have to touch the gas control valve. If you would like the
fireplace off for a while, just set the thermostat to its minimum setting. However if you do not
need the fireplace for quite some time, follow the procedure outlined in the SHUTDOWN
section. This will extinguish the pilot light as well.
SHUTDOWN
Push in and rotate the gas control knob clockwise to the "off" position. Do not force.
If you are going to perform any maintenance or cleaning, first allow the fireplace to cool
completely. Follow the instructions in the section on cleaning under MAINTENANCE
INSTRUCTIONS.
BLOWER
The blower control contains a variable speed switch and a thermal switch. When the fireplace is
operating, the thermal switch will turn on at 120° F, allowing the blower to operate . When the
fireplace cools to 90° F, the thermal switch turns off the blower in about 40 minutes. This
prevents the blower from operating when the fireplace is not in use.
The blower not only helps circulate air throughout the room, it also increases the heat output and
efficiency of the ULTRA FLAME.
7