beautypg.com

Specifications – Drolet Ultra Flame DG05437/DG05447 User Manual

Page 5

background image

ULTRA FLAME DV “0” Clearance Fireplace

SPECIFICATIONS

Dimensions:

height 39", width 36", depth 20"


Glass:

29-1/8" x 17-3/4" 1400oF clear ceramic


Minimum opening in wall for installing the units:

height:

39-1/2"

width:

36-1/2"


Fuel:

Natural Gas

Propane

Input :

30,000/ 20,000 26,000/20,000

Btu/h

Manifold pressure :

3.5/1.8

10.5/7.0

in w.c.

Min. inlet pressure :

5

11

in w.c.

Max. inlet pressure :

7

14

in w.c.

Efficiency:

75%


Vent size:

4" inner 8" outer coaxial vent pipes


Valve:

SIT Model Nova 820 adjustable millivolt valve


Blower:

Variable speed, 200 CFM


Thermo-switch:

120oF "ON", 90oF "OFF" bi-metal type


Pressure relief device: Burst disc

Maximum length of venting pipe allowed:

Straight out installation:

- Vertical rise: 0’

-

Max

horizontal

length:

5'

-

Max

combination

of

both:

5’


Corner installation:

- Vertical rise: 0’

-

Max

horizontal

length:

5'

-

Max

combination

of

both:

5’


Basement installation:

- Max vertical rise: 25'

-

Max

horizontal

length:

10'

- Max combination of both: 25'

Maximum number of elbows 90

° or 45°: 3

5