Specifications – Drolet Ultra Flame DG05437/DG05447 User Manual
Page 5
ULTRA FLAME DV “0” Clearance Fireplace
SPECIFICATIONS
Dimensions:
height 39", width 36", depth 20"
Glass:
29-1/8" x 17-3/4" 1400oF clear ceramic
Minimum opening in wall for installing the units:
height:
39-1/2"
width:
36-1/2"
Fuel:
Natural Gas
Propane
Input :
30,000/ 20,000 26,000/20,000
Btu/h
Manifold pressure :
3.5/1.8
10.5/7.0
in w.c.
Min. inlet pressure :
5
11
in w.c.
Max. inlet pressure :
7
14
in w.c.
Efficiency:
75%
Vent size:
4" inner 8" outer coaxial vent pipes
Valve:
SIT Model Nova 820 adjustable millivolt valve
Blower:
Variable speed, 200 CFM
Thermo-switch:
120oF "ON", 90oF "OFF" bi-metal type
Pressure relief device: Burst disc
Maximum length of venting pipe allowed:
Straight out installation:
- Vertical rise: 0’
-
Max
horizontal
length:
5'
-
Max
combination
of
both:
5’
Corner installation:
- Vertical rise: 0’
-
Max
horizontal
length:
5'
-
Max
combination
of
both:
5’
Basement installation:
- Max vertical rise: 25'
-
Max
horizontal
length:
10'
- Max combination of both: 25'
Maximum number of elbows 90
° or 45°: 3
5