ULTRA FLAME DV “0” Clearance Fireplace
GLASS FRONT REMOVAL, CLEANING AND INSTALLATION
Removal :
• Let the fireplace cool down for at least one hour.
• Open top and bottom louvres exposing the front retaining clamps
• Open the four clamps (bottom 2 first)
• Remove the glass front assembly.
CAUTION : Do not operate your fireplace without a glass front or with a broken glass.
Cleaning :
• Only clean the glass when cold.
• Clean with liquid type cleaners or soap and water; do not use abrasive cleaners,
which can scratch the glass.
Installation :
• Put the glass front assembly back in position.
• Insert the hooks of all four clamps into the glass front.
• Tighten both top clamps simultaneously.
• Tighten both bottom clamps simultaneously.
• Close the louvres.
BURNER REMOVAL AND INSTALLATION
REMOVAL :
• Remove the glass front assembly.
• Lift out the grate and hearth insert around burner.
• Unscrew the retaining screws on each side of the burner.
• Slide burner to the left and lift out.
22