INSTALLATION
ACTUAL TERMINAL LOCATION
The connecting terminals are located inside the chassis. Two identical rows of the terminals are provided,
one is to connect incoming wires and the other is to connect outgoing wires.
Incoming “
TT
Jol
la
mini] : Terminals for 1st talk channel
Connect to terminals 1,2 of the next Station.
: Terminals for 2nd talk channel
Connect to terminals 3, 4 of the next Station,
mjllill ■ Terminals for 3rd talk channel
Connect to terminals 5, 6 of the next Station.
'[±]im
■ Terminals for Power supply
Connect to terminals +, - of the next Station.
Outgoing
Inside view of
YAZ-90-3W chassis
SETTING YOUR STATION NUMBER
STATION
STEP #1
Assign a Station number from 10 through 99.
• The YAZ-90-3W system does not require central
exchange unit and, therefore, assigning
Station number must be done on each Station.
• The YAZ-90-3W Station may have any number
from 10 through 99 according to users’
convenience.
• Be sure to assign a Station number for every
installed Station otherwise that Station would not
be able to receive calls.
» Do not assign a same number to more than one
Station.
STEP #2
On the DIP SWITCH section (back of the unit),
locate the switches to verify the STATION number
for the station.
Example; STATION #12
1 2 4 8 1 1 2 4 8
10
:#12
STATION NUMBER CARD
' Using the minus-head screwdriver, push either
end of the transparent cover.
> Fill in your Station number programmed on the
card.
- 3 -