2. function list – A&D Digital Platform Scales FG-60KAM User Manual
Page 16
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
9-2. Function list
Item •
Description
Auto power-off
function
F I - 0
Auto power-off disabled
Automatically
power off
♦ F
1
-
1
Auto power-off enabled for battery
use only
F
/- F-
Auto power-off enabled for battery
and AC adapter
Display
resolution
F E - B
Normal (1/3,000 class)
Legal for trade
will be Normal.
*
F E - 1
High (1/6,000-1/7,500 class)
F E - E
Higher (1/12,000-1/15,000 class)
Weighing unit
when powered
on
^
F 3 - Q
lb ,
U.S.A. models
only
F 3 - 1
oz
F 3 - E
kg______________________________
RS-232C
Baud rate
*
F 3 - B
2400 bps
F 3 - 1
4800 bps
F 3 - E
9600 bps
RS-232C
Data output
mode
*
F 5 - B
Stream mode
F 5- /
Command mode
F 5- г
Print switch mode
F 5- 3
Auto-print mode +/- data
F 5 - 3
Auto-print mode + data
Comparator
mode
*
F B - B
Comparator disabied
Conditions to
compare,
d = minimum
display division
F B - 1
Compares all data
F B - E
Compares data > +4d or < -4d
F B - 3
Compares all stable data
F B - 3
Compares stable data > +4d or < -4d
Filtering to
weighing data
F 1 - B
Weak / fast response
*
F 1 - 1
Normal / normal response
F E
Strong / slow response
RS-232C
Data format
^
F B - B
Reply is sent
Reaction to the
command
F B - 1
No reply except "Q” command
Factory setting
15